Free shipping on all orders over $50
7-15 days international
10 people viewing this product right now!
30-day free returns
Secure checkout
92225951
content="Sheets" name="generator">
Part Number | Item Description |
FLUKE-750PD27 | Pressure Module, -1 to 1 Psi (-70 to 70 Mbar) |
FLUKE-750PD3 | Pressure Module, -5 to 5 Psi (-350 to 350 Mbar) |
FLUKE-750PD10 | Pressure Module, -10 to 10 Psi (-700 to 700 Mbar) |
FLUKE-750PD4 | Pressure Module, -15 to 15 Psi (-1 to 1 Bar) |
FLUKE-750PD5 | Pressure Module, -15 to 30 Psi (-1 to 2 Bar) |
FLUKE-750PD50 | Pressure Module, -15 to 50 Psi (-1 to 3.5 Bar) |
FLUKE-750PD6 | Pressure Module, -15 to 100 Psi (-1 to 7 Bar) |
FLUKE-750PD7 | Pressure Module, -15 to 200 Psi (-1 to 14 Bar) |
FLUKE-750PD27 | Pressure Module, -15 to 300 Psi (-1 to 20 Bar) |
Precision Pressure Measurement for 75X and 720 Series Calibrators
The 750P Series Pressure Modules are the ideal pressure modules to enable gage, differential and absolute pressure measurement with Fluke 750 and 740 series DPCs and 725, 726 MPCs to measure pressure.
A Complete Family of Pressure Modules
A family of 50 pressure modules covers pressure calibrations from 0 to 1 inH20 to 10,000 psi (2.5 mBar to 690 bar).
Gage pressure modules have one pressure fitting and measure the pressure with respect to atmospheric pressure. Differential pressure modules have two pressure fittings and measure the difference between the applied pressure on the high fitting versus the low fitting. Each module is clearly labeled for pressure range and media compatibility. All modules include NPT, metric (BSP) and M20 adapters. Compatible with all documenting, multifunction and pressure calibrators (including: Fluke 754, 752, 726, 725, 721, 719Pro, 719, 717 and legacy 741, 743, 744, 701 and 702 calibrators).
Quick and Easy Measurements
Fluke 750P Series Pressure Modules are easy to use. To measure pressure, connect the pressure module to a pressure source or hand pump and then connect the pressure module cable to the calibrator. Apply pressure from the pressure source and it is displayed digitally on the calibrator. At the touch of a button, the pressure may be displayed in up to 11 different engineering units. When used with the 750 Series Documenting Process Calibrators, pressure readings can be date/time stamped and stored electronically for later retrieval. This saves time, eliminates errors, and supports compliance with quality standards and regulations.
Choose from:
Other useful features:
Differential Module Specifications | |||||
Model | Parameter / range | Burst rating6 | Hi side media2 | Lo side media2 | |
750P00 | 0 to 1 inH2O (0 to 2.5 mBar) | 30X | Dry air | Dry air | |
750P3IN | 0 to 3 Inch H2O (0 to 7.5 mbar) | 10X | Dry air | Dry air | |
750P5IN | 0 to 5 Inch H2O (0 to 12.5 mbar) | 6X | Dry air | Dry air | |
750P017 | 0 to 10 inH2O (0 to 25 mBar) | 3X | Dry air | Dry air | |
750P02 | 0 to 1 psi (0 to 70 mBar) | 3X | Dry air | Dry air | |
750P22 | 0 to 1 psi (0 to 70 mBar) | 3X | 316 SS | Dry air | |
750P03 | 0 to 5 psi (0 to 350 mBar) | 3X | Dry air | Dry air | |
750P23 | 0 to 5 psi (0 to 350 mBar) | 4X | 316 SS | Dry air | |
750P04 | 0 to 15 psi (0 to 1 bar) | 3X | Dry air | Dry air | |
750P247 | 0 to 15 psi (0 to 1 bar) | 4X | 316 SS | Dry air | |
Model | Reference uncertainty4 | Total uncertainty 1-year (15-35°C) | Total uncertainty 1-year1 | Total uncertainty 6-month (15-35°C) | Total uncertainty 6-month1 |
750P00 | ±0.15% | ±0.3% | ±0.35% | ±0.25% | ±0.30% |
750P3IN | ±0.15% | ±0.3% | ±0.35% | ±0.25% | ±0.30% |
750P5IN | ±0.15% | ±0.3% | ±0.35% | ±0.25% | ±0.30% |
750P017 | ±0.1% | ±0.2% | ±0.3% | ±0.15% | ±0.25% |
750P02 | ±0.050% | ±0.1% | ±0.15% | ±0.075% | ±0.125% |
750P22 | ±0.050% | ±0.1% | ±0.15% | ±0.075% | ±0.125% |
750P03 | ±0.02% | ±0.04% | ±0.05% | ±0.035% | ±0.04% |
750P23 | ±0.02% | ±0.04% | ±0.05% | ±0.035% | ±0.04% |
750P04 | ±0.0175% | ±0.035% | ±0.045% | ±0.03% | ±0.04% |
750P247 | ±0.0175% | ±0.035% | ±0.045% | ±0.03% | ±0.04% |
Gage Module Specifications | |||||
Model | Parameter / range | Burst rating6 | Hi side media2 | Lo side media2 | |
750P057 | 0 to 30 psi (0 to 2 bar) | 4X | 316 SS | N/A | |
750P067 | 0 to 100 psi (0 to 7 bar) | 4X | 316 SS | N/A | |
750P277 | 0 to 300 psi (0 to 20 bar) | 4X | 316 SS | N/A | |
750P07 | 0 to 500 psi (0 to 35 bar) | 4X | 316 SS | N/A | |
750P08 | 0 to 1000 psi (0 to 70 bar) | 3X | 316 SS | N/A | |
750P097 | 0 to 1500 psi (0 to 100 bar) | 3X | 316 SS | N/A | |
750P2000 | 0 to 2000 psi (0 to 140 bar) | 3X | 316 SS | N/A | |
Model | Reference uncertainty4 | Total uncertainty 1-year (15-35°C) | Total uncertainty 1-year1 | Total uncertainty 6-month (15-35°C) | Total uncertainty 6-month1 |
750P057 | ±0.0175% | ±0.035% | ±0.045% | ±0.03% | ±0.04% |
750P067 | ±0.0175% | ±0.035% | ±0.045% | ±0.03% | ±0.04% |
750P277 | ±0.0175% | ±0.035% | ±0.045% | ±0.03% | ±0.04% |
750P07 | ±0.0175% | ±0.035% | ±0.045% | ±0.03% | ±0.04% |
750P08 | ±0.0175% | ±0.035% | ±0.045% | ±0.03% | ±0.04% |
750P097 | ±0.0175% | ±0.035% | ± 0.045% | ±0.03% | ±0.04% |
750P2000 | ±0.0175% | ±0.035% | ± 0.045% | ±0.03% | ±0.04% |
High Pressure Module Specifications | |||||
Model | Parameter / range | Burst rating6 | Hi side media2 | Lo side media2 | |
750P29 | 0 to 3000 psi (0 to 200 bar) | 3X | 316 SS | N/A | |
750P30 | 0 to 5000 psi (0 to 340 bar) | 3X | 316 SS | N/A | |
750P31 | 0 to 10000 psi (0 to 700 bar) | 2X | 316 SS | N/A | |
Model | Reference uncertainty4 | Total uncertainty 1-year (15-35°C) | Total uncertainty 1-year1 | Total uncertainty 6-month (15-35°C) | Total uncertainty 6-month1 |
750P29 | ±0.0175% | ±0.035% | ±0.045% | ±0.03% | ±0.04% |
750P30 | ±0.0175% | ±0.035% | ±0.045% | ±0.03% | ±0.04% |
750P31 | ±0.0175% | ±0.035% | ±0.045% | ±0.03% | ±0.04% |
Absolute Module Specifications | |||||
Model | Parameter / range | Burst rating6 | Hi side media2 | Lo side media2 | |
750PA3 | 0 to 5 psia (0 to 350 mBar) | 4X | 316 SS | N/A | |
750PA47 | 0 to 15 psia (0 to 1 bar) | 4X | 316 SS | N/A | |
750PA5 | 0 to 30 psia (0 to 2 bar) | 4X | 316 SS | N/A | |
750PA6 | 0 to 100 psia (0 to 7 bar) | 4X | 316 SS | N/A | |
750PA27 | 0 to 300 psia (0 to 20 bar) | 4X | 316 SS | N/A | |
750PA7 | 0 to 500 psia (0 to 35 bar) | 4X | 316 SS | N/A | |
750PA8 | 0 to 1000 psia (0 to 70 bar) | 3X | 316 SS | N/A | |
750PA9 | 0 to 1500 psia (0 to 100 bar) | 3X | 316 SS | N/A | |
Model | Reference uncertainty4 | Total uncertainty 1-year (15-35°C) | Total uncertainty 1-year1 | Total uncertainty 6-month (15-35°C) | Total uncertainty 6-month1 |
750PA3 | ±0.03% | ±0.06% | ±0.07% | ±0.05% | ±0.06% |
750PA47 | ±0.03% | ±0.06% | ±0.07% | ±0.05% | ±0.06% |
750PA5 | ±0.03% | ±0.06% | ±0.07% | ±0.05% | ±0.06% |
750PA6 | ±0.03% | ±0.06% | ±0.07% | ±0.05% | ±0.06% |
750PA27 | ±0.03% | ±0.06% | ±0.07% | ±0.05% | ±0.06% |
750PA7 | ±0.03% | ±0.06% | ±0.07% | ±0.05% | ±0.06% |
750PA8 | ±0.03% | ±0.06% | ±0.07% | ±0.05% | ±0.06% |
750PA9 | ±0.03% | ±0.06% | ±0.07% | ±0.05% | ±0.06% |
Vacuum Module Specifications | |||||
Model | Parameter / range | Burst rating6 | Hi side media2 | Lo side media2 | |
750PV3 | -5 psi (-350 mBar) | 4X | 316 SS | Dry air | |
750PV4 | -15 psi (-1 bar) | 4X | 316 SS | Dry air | |
Model | Reference uncertainty4 | Total uncertainty 1-year (15-35°C) | Total uncertainty 1-year1 | Total uncertainty 6-month (15-35°C) | Total uncertainty 6-month1 |
750PV3 | ±0.03% | ±0.06% | ±0.07% | ±0.05% | ±0.06% |
750PV4 | ±0.03% | ±0.06% | ±0.07% | ±0.05% | ±0.06% |
Dual Range Specifications | |||||
Model | Parameter / range | Burst rating6 | Hi side media2 | Lo side media2 | |
750PD2 | -1 to 1 psi (-70 to 70 mBar) | 4X | 316 SS | Dry air | |
750PD3 | -5 to 5 psi (-350 to 350 mBar) | 4X | 316 SS | Dry air | |
750PD10 | -10 to 10 psi (-700 to 700 mBar) | 4X | 316 SS | Dry air | |
750PD4 | -15 to 15 psi (-1 to 1 bar) | 4X | 316 SS | Dry air | |
750PD5 | -15 to 30 psi (-1 to 2 bar) | 4X | 316 SS | — | |
750PD50 | -15 to 50 psi (-1 to 3.5 bar) | 4X | 316 SS | — | |
750PD6 | -15 to 100 psi (-1 to 7 bar) | 4X | 316 SS | — | |
750PD7 | -15 to 200 psi (-1 to 14 bar) | 4X | 316 SS | — | |
750PD27 | -15 to 300 psi (-1 to 20 bar) | 4X | 316 SS | — | |
Model | Reference uncertainty4 | Total uncertainty 1-year (15-35°C) | Total uncertainty 1-year1 | Total uncertainty 6-month (15-35°C) | Total uncertainty 6-month1 |
750PD2 | ±0.05% | ±0.1% | ±0.15% | ±0.075% | ±0.125% |
750PD3 | ±0.03% | ±0.06% | ±0.07% | ±0.05% | ±0.06% |
750PD10 | ±0.025% | ±0.05% | ±0.07% | ±0.04% | ±0.06% |
750PD4 | ±0.0175% | ±0.035% | ±0.045% | ±0.03% | ± 0.04% |
750PD5 | ± 0.0175% | ± 0.035% | ± 0.045% | ±0.03% | ± 0.04% |
750PD50 | ± 0.0175% | ± 0.035% | ± 0.045% | ±0.03% | ± 0.04% |
750PD6 | ± 0.0175% | ± 0.035% | ± 0.045% | ±0.03% | ± 0.04% |
750PD7 | ± 0.0175% | ± 0.035% | ± 0.045% | ±0.03% | ± 0.04% |
750PD27 | ± 0.0175% | ± 0.035% | ± 0.045% | ±0.03% | ± 0.04% |
Reference Module Specifications | |||||
Model | Parameter / range | Burst rating6 | Hi side media2 | Lo side media2 | |
750R045 | 0 to 15 psi (0 to 1 bar) | 3X | Dry air | Dry air | |
750R065 | 0 to 100 psi (0 to 7 bar) | 4X | 316 SS | — | |
750R27 | 0 to 300 psi (0 to 20 bar) | 4X | 316 SS | — | |
750R07 | 0 to 500 psi (0 to 35 bar) | 4X | 316 SS | — | |
750R085 | 0 to 1000 psi (0 to 70 bar) | 3X | 316 SS | — | |
750R29 | 0 to 3000 psi (0 to 200 bar) | 3X | 316 SS | — | |
750R30 | 0 to 5000 psi (0 to 340 bar) | 3X | 316 SS | — | |
750R315 | 0 to 10000 psi (0 to 700 bar) | 2X | 316 SS | — | |
750RD5 | -15 to 30 psi (-1 to 2 bar) | 4X | Dry air | — | |
750RD65 | -12 to 100 psi (-0.8 to 7 bar) | 4X | 316 SS | — | |
750RD27 | -12 to 300 psi (-0.8 to 20 bar) | 4X | 316 SS | — | |
Model | Reference uncertainty4 | Total uncertainty 1-year (15-35°C) | Total uncertainty 1-year1 | Total uncertainty 6-month (15-35°C) | Total uncertainty 6-month1 |
750R045 | ±0.01% of FS | ±0.02% of FS | ±0.04% of FS | ±0.015% of FS | ±0.035% of FS |
750R065 | ±0.01% of FS | ±0.02% of FS | ±0.04% of FS | ±0.015% of FS | ±0.035% of FS |
750R27 | ±0.01% of FS | ±0.02% of FS | ±0.04% of FS | ±0.015% of FS | ±0.035% of FS |
750R07 | ±0.01% of FS | ±0.02% of FS | ±0.04% of FS | ±0.015% of FS | ±0.035% of FS |
750R085 | ±0.01% of FS | ±0.02% of FS | ±0.04% of FS | ±0.015% of FS | ±0.035% of FS |
750R29 | ±0.01% of FS | ±0.02% of FS | ±0.04% of FS | ±0.015% of FS | ±0.035% of FS |
750R30 | ±0.01% of FS | ±0.02% of FS | ±0.04% of FS | ±0.015% of FS | ±0.035% of FS |
750R315 | ±0.01% of FS | ±0.02% of FS | ±0.04% of FS | ±0.015% of FS | ±0.035% of FS |
750RD5 | ±0.01% of FS | ±0.02% of FS | ±0.04% of FS | ±0.015% of FS | ±0.035% of FS |
750RD65 | ±0.01% of FS | ±0.02% of FS | ±0.04% of FS | ±0.015% of FS | ±0.035% of FS |
750RD27 | ±0.01% of FS | ±0.02% of FS | ±0.04% of FS | ±0.015% of FS | ±0.035% of FS |
1. Total uncertainty, % of full span for temperature range 0°C to +50°C, one year interval. Total uncertainty, 1.0% of full span for temperature range -10°C to 0°C, one year interval. No 6 month specification available for range -10°C to 0°C. 2. “Non-corrosive gasses” indicates Dry air or non-corrosive gas as compatible media. “Stainless Steel 316-SS” indicates media compatible with Type 316 Stainless Steel. 3. Specifications % of Full Span unless otherwise noted. 4. Reference Uncertainty is the specification for as left data for 24 hours. 5. When reference class modules are used with fixed resolution products (717, 718, 719 series, 725 and 726) calibrators add ±1 count to the overall accuracy specification. 6. Burst rating specification refers to the multiplier times full scale of the module for the rated burst pressure. 7. Intrinsically Safe pressure module available in this pressure range. |